Velleman HAA50 Manuel d'utilisateur Page 4

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 3
HAA50 VELLEMAN
4
9. Specifications
Detection Pattern : conical pattern, 360°. Detection area with a Ø of 36ft (11m) if the
detector is attached to a 12ft-ceiling (3.6m).
Operating Voltage : 8-16VDC
Quiescent Current : 15mA nominal at 12VDC
Relay Output : N.C. (Normally Closed)
Activation Delay : 2 to 3 seconds
Alarm Output : N.C. (fail-safe) dry relay contact of 0.5A / 24VDC, 18-resistor
connected in series with the contact
Tamper Output : N.C. dry contact (Normally Closed) of 0.5A / 24VDC
LED : indicates detection, can be switched off
Pulse Counter : single- or double-pulse detection, detection through alternating polarity
of the signal
Mounting Height : max. 12ft (3.6m)
All specifications are subject to modification without prior notice.