CU2200_v5 VELLEMAN 6
Example:
ST:001;T:2005/01/27/12:00;V:8.14;A1:2312;A2:2131;K1:1;K2:0;K3:0;K4:1; O:1#
ST Unit serial number 001
T Unit internal clock Date: 27 Jan 2005, time: 12h00
V Operating voltage 8.14VDC
K1 Alarm channel 1 1 Open
K2 Alarm channel 2 0 Closed
K3 Alarm channel 3 0 Closed
K4 Alarm channel 4 1 Open
O Relay output 1 1 On
• Power-Up Message
Whenever the unit is powered up, it will automatically send RESTART! to the control centre.
• System Clock Setup
Command: PWD:XXXX,TIME:AABBCCDDEE%
XXXX Password
AABBCCDDEE Year/month/day/hour/minute
Example:
PWD:1234,TIME:0602031327%
Password: 1234
Clock: 3 Feb 2006, 13h27
• Phone Number Setup
Command: PWD:XXXX,ALMNU1:ZZZZZZZZZZZ,2:ZZZZZZZZZZZ,3:ZZZZZZZZZZZ,4:ZZZZZZZZZZZ#%
XXXX Password
ZZZZZZZZZZZ Phone number
Example 1:
PWD:1234,ALMNU1:12345678,2:36925814712,3:159357456,4:951753654#%
Password 1234
When the alarm is triggered, an SMS message is sent to following numbers:
N° 1 12345678
N° 2 36925814712
N° 3 159357456
N° 4 951753654
Example 2:
PWD:1234,ALMNU1:NUL,3:NUL#%
Password 1234
With example 1, following numbers have been cancelled:
N° 1 12345678, not made
N° 2 36925814712, retained
N° 3 159357456, not made
N° 4 951753654, retained